J. Castro-Gómez | Instituto Tecnológico de Hermosillo |
G. Valencia-Palomo | Instituto Tecnológico de Hermosillo |
O. Hernández-González | CONACYT-Instituto Tecnológico de Hermosillo |
M.E. Guerrero-Sánchez | CONACYT-Instituto Tecnológico de Hermosillo |
F. Ramírez-Rasgado | Centro Nacional de Investigación y Desarrollo Tecnológico |
C.-M. Astorga-Zaragoza | Centro Nacional de Investigación y Desarrollo Tecnológico |
https://doi.org/10.58571/CNCA.AMCA.2022.069
Resumen: This paper presents a control strategy for plasma glucose regulation in the presence of input with unknown time delay (constant or variable) and meal disturbances in the system. The control scheme proposed is an observer-based state feedback controller. The observer achieves to estimate the state vector even if the control input in the system presents an unknown time delay in the input. The main advantage of the controller is that the gains are selected so the control law will provide positive values that ensure an implementable case. The observer-based control scheme is validated considering different disturbance and unknown delays scenarios, in both cases, glucose regulation is achieved, rejecting meal disturbances in 4 hours and avoiding hypoglycemic episodes.
¿Cómo citar?
J. Castro-Gómez, F. Ramírez-Rasgado, O. Hernández-González, C.-M. Astorga-Zaragoza, G. Valencia-Palomo & M.E. Guerrero-Sánchez. Control for plasma glucose regulation in type 1 diabetes mellitus patients with unknown input delays. Memorias del Congreso Nacional de Control Automático, pp. 386-391, 2022. https://doi.org/10.58571/CNCA.AMCA.2022.069
Palabras clave
Control de Sistemas No Lineales; Procesos Biológicos; Sistemas Biomédicos
Referencias
- Apablaza, P., Soto, N., and Codner, E. (2017). De la bomba de insulina y el monitoreo continuo de glucosa al páncreas artificial. Revista Médica de Chile, 145, 630–640.
- Borri, A., Cacace, F., De Gaetano, A., Germani, A., Manes, C., Palumbo, P., Panunzi, S., and Pepe, P. (2017). Luenberger-like observers for nonlinear time-delay systems with application to the artificial pancreas: The attainment of good performance. IEEE Control Systems Magazine, 37(4), 33–49.
- Ghanes, M., De Leon, J., and Barbot, J.P. (2013). Observer design for nonlinear systems under unknown time-varying delays. IEEE Transactions on Automatic Control, 58(6), 1529–1534.
- González, R. and Cipriano, A. (2016). Control difuso con estimador de estados para sistemas de páncreas artificial. RIAI – Revista Iberoamericana de Automática e Informática Industrial, 13, 393–Fig. 10. Señal de control Escenario 2, u(t). 402.
- Lechappe, V., de Leon, J., Moulay, E., Plestan, F., and Glumineau, A. (2017). Delay and state observation for siso nonlinear systems with input delay. International Journal of Robust and Nonlinear Control, 28, 2356–2368.
- Magdelaine, N., Chaillous, L., Guilhem, I., Poirier, J.Y., Krempf, M., Moog, C.H., and Le Carpentier, E. (2015). A long-term model of the glucose-insulin dynamics of type 1 diabetes. IEEE Transactions on Biomedical Engineering, 62, 1546–1552.
- Messori, M., Toffanin, C., Del Favero, S., De Nicolao, G., Cobelli, C., and Magni, L. (2016). Model individualization for artificial pancreas. Computer Methods and Programs in Biomedicine, 171, 133–140.
- Nath, A. and Dey, R. (2019a). Observer based nonlinear control design for glucose regulation in type 1 diabetic patients: An lmi approach. Biomedical Signal Processing and Control, 47, 7–15.
- Nath, A. and Dey, R. (2019b). Robust observer based control for plasma glucose regulation in type 1 diabetes patient using attractive ellipsoid method. IET Systems Biology, 13(2), 84–91.
- Ramírez-Rasgado, F., Galaz-Palma, R.R., Hernández -González, O., Astorga-Zaragoza, C.M., Guerrero-Sánchez, M.E., Valencia-Palomo, G., and Targui, B. (2020). Control basado en observador para el desplazamiento de estructuras con retardo en la señal de control. In Jornada de Ciencia y Tecnolog´ıa Aplicada, volume 3, 121–125.
- Rudin, W. (1976). Principles of mathematical analysis. McGraw-Hill.
- Sereno, J., Caicedo, M., and Rivadeneira, P. (2018). Artificial pancreas: glycemic control strategies for avoiding hypoglycemia. DYNA, 85(207), 187–207.
- Toledo Enriquez, D., González Santos, A., Toledano Hernández, A., Iglesias Benítez, A., Martínez-Casado, J., and Gonzáles Aguilera, D. (2015). Controlador predictivo para la infusión subcutánea de insulina en un páncreas artificial. Revista Cubana de Ciencias Informáticas, 9(2), 81–98.